TECHNICAL DATA
- Max. Operating Temperature: 90°C
- Max. Short Circuit Temperature: (max. 5 sec.) 200°C
- Rated Voltage: 150/250V
- Min. Bending Radius: 6x Cable Outer Diameter
- Production Standard: IEC 60092/353,
IEC 60092/350-360, IEC 60332/1-2,
IEC 60332/3-22 Cat A, IEC 60754 / 1-2,
IEC 61034 / 1-2 (DIN EN 50268 / 1-2), IEC60811 /403
CONSTRUCTION
- Conductor: Electrolytic, stranded, annealed copper wire IEC 60228 Class 2 (Class 5 and / or tinned on request)
- Fire Barrier: Mica Tape
- Insulation: Cross linked polyethylene compound (XLPE)
- Inner Covering: Separating foil
- Screen: Electrolytic, tinned, stranded, copper drain wire and aluminium tape overall screen
- Seperator(Optional): Separating foil above screen )
- Outer Sheath: Halogen-free, flame retardant, polyolefin based compound (SHF 1)
- Color: Orange or Green
CODE of CABLE
- FM2XAH -FFR
APPLICATION
These cables are used as signal and communication cables in radio, radar and information systems of marine vehicles. It’s twisted pairs enables proper transmission of high frequency signals, while it’s overall screen minimizes environmental electromagnetic interference.
SECTION RANGE
- From 0.5mm2 up to 1.5mm2
CONDUCTOR QUANTITY
- From 1 core up to 37 cores
COLOUR CODE of CABLE
- Insulation Colours code could be according to the
International Standards or customer’s request/demand.
* Other colours can be produced upon the customer
requests.