TECHNICAL DATA
- Max. Operating Temperature: 90°C
- Max. Short Circuit Temperature: (max. 5 sec.) 200°C
- Rated Voltage: 0,6/1kV
- Min. Bending Radius:
For cables D ≤ 25 mm 4xD Cable Outer Diameter
For cables D > 25 mm 6xD Cable Outer Diameter - Production Standard: IEC 60092/353,
IEC 60092/350-360, IEC 60332/1-2,
IEC 60332/3-22 Cat A, IEC 60754 / 1-2,
IEC 61034 / 1-2 ( DIN EN 50268 / 1-2), IEC60811 /403
CONSTRUCTION
- Conductor: Electrolytic, stranded, annealed copper wire
IEC 60228 Class 5 (Class 2 and / or tinned on request) - Insulation: Cross linked polyethylene compound (XLPE)
- Inner Covering: Halogen-free bedding compound
- Outer Sheath: Halogen-free, flame retardant, thermoplastic
polyolefinbased compound (SHF 1). - Color: Black or Grey or Red
- FI: With extruded bedding compound
CODE of CABLE
- M2XH (FI)
APPLICATION
These cables are used as fixed installation cables in various
electromechanical and electronic equipments of marine
vehicles, in the majority of areas and on the open deck of ships.
SECTION RANGE
- From 1mm2 up to 240mm2
CONDUCTOR QUANTITY
- From 2 cores up to 24 cores
COLOUR CODE of CABLE
- Insulation Colours code could be according to the
International Standards or customer’s request/demand.
* Other colours can be produced upon the customer
requests.