SupremeFlex-SmF-M2XCH-FFR

TECHNICAL DATA

  • Max. Operating Temperature: 90°C
  • Max. Short Circuit Temperature: (max. 5 sec.) 200°C
  • Rated Voltage: 0,6/1kV
  • Min. Bending Radius: 6x Cable Outer Diameter
  • Production Standard: IEC 60092/353,
    IEC 60092/350-360, IEC 60332/1-2,
    IEC 60332/3-22 Cat A, IEC 60754 / 1-2,
    IEC 61034 / 1-2 (DIN EN 50268 / 1-2), IEC60811 /403

CONSTRUCTION

  • Conductor: Electrolytic, stranded, annealed sector shaped copper wire to IEC 60228 Class 5 SM (Tinned on request)
  • Fire Barrier: Mica tape
  • Insulation: Cross linked polyethylene compound (XLPE)
  • Inner Covering: Separating foil
  • Outer Sheath: Halogen-free, flame retardant and fire resistant, thermoplastic polyolefin based compound (SHF1)
  • Color: Orange or Green

CODE of CABLE

  • SupremeFlex SmF M2XCH-FFR

APPLICATION

These cables are used as fixed installation cables in various electromechanical and electronic equipments of marine vehichles, in most areas & open deck in ships. Due to its’ overall screen the electromagnetic interference is minimized.

SECTION RANGE

  • From 35mm2 up to 240mm2

CONDUCTOR QUANTITY

  • From 3 core up to 4 cores

COLOUR CODE of CABLE

  • Insulation Colours code could be according to the
    International Standards or customer’s request/demand.
    * Other colours can be produced upon the customer
    requests.

Inquiry Form