TECHNICAL DATA
- Max. Operating Temperature: 90°C
- Max. Short Circuit Temperature: (max. 5 sec.) 200°C
- Rated Voltage: 0,6/1kV
- Production Standard: BS 6883, IEC 60092/353,
IEC 60092/350-360, IEC 60332/1-2,
IEC 60332/3-22 Cat A, IEC 60754 / 1-2,
IEC 61034 / 1-2 (DIN EN 50268 / 1-2), IEC60811 /403
CONSTRUCTION
- Conductor: Tinned stranded copper in accordance with
IEC 60228 CL2, CL5 - Insulation: Ethylene Propylene Rubber (EPR), GP4 in
accordance with BS 7655-1.2 - Outer Jacket: Halogen free extruded compound, SW4 in
accordance with BS 7655-2.6 - Color: Black
CODE of CABLE
- U-8RW4; CU/EPR/SW4
APPLICATION
These cables are used for fixed installation for power, control
and lighting in both and safe areas, emergency and critical
offshore applications.
SECTION RANGE
- From 1mm2 up to 300mm2
CONDUCTOR QUANTITY
- From 1 core up to 35 cores
COLOUR CODE of CABLE
- Insulation Colours code could be according to the
International Standards or customer’s request/demand.
* Other colours can be produced upon the customer
requests.