RFOU-VFD

TECHNICAL DATA

  • Max. Operating Temperature: 90°C
  • Max. Short Circuit Temperature: (max. 5 sec.) 200°C
  • Rated Voltage: 0,6/1kV
  • Min. Bending Radius: 8x Cable Outer Diameter
  • Production Standard: NEK TS 606, IEC 60092/353, IEC 60092/350-360, IEC 60332/1-2,
    IEC 60332/3-22 Cat A, IEC 60754 / 1-2,
    IEC 61034 / 1-2 (DIN EN 50268 / 1-2), IEC60811 /403

CONSTRUCTION

  • Conductor: Plain or tinned annealed stranded circular copper, IEC 60228, Class 2 or Class 5
  • Earthing Conductor: Plain or tinned annealed stranded circular copper, IEC 60228, Class 2 or Class 5
  • Insulation: Hard grade Ethylene Propylene Rubber (HEPR)
  • Screen: Metal coated polyester tape + tinned or bare copper wire braid
  • Inner Sheath: Flame retardant and halogen-free compound
  • Armour: Tinned or bare copper wire braid
  • Outer Sheath: Flame retardant, halogen-free thermoset compound, SHF2
  • Color: Black

CODE of CABLE

  • RFOU VFD

APPLICATION

These cables are used for fixed installation for control, instrumentation and telecommunication in both explosion and safe areas, emergency and critical systems where requirement for fire resistance exists.

SECTION RANGE

  • From 25mm2 up to 185mm2

CONDUCTOR QUANTITY

  • 3 cores

COLOUR CODE of CABLE

  • Insulation Colours code could be according to the
    International Standards or customer’s request/demand.
    * Other colours can be produced upon the customer
    requests.

Inquiry Form